Server Technology PRO2 24-Outlets PDU

Part No. C2WG24TB-5QCD27T0

by Server Technology, Inc

Server Technology PRO2 24-Outlets PDU

Switched - IEC 60309 3P+N+G 6Hr 60A - 24 x CX - 415 V AC, 230 V AC - Branch Circuit, Circuit Protection, Circuit Breaker, Fuse - Network (RJ-45) - Rack-mountable, Cabinet-mountable

Part No. C2WG24TB-5QCD27T0

by Server Technology, Inc

$7123.99
General Information
ManufacturerServer Technology, Inc
Manufacturer Part NumberC2WG24TB-5QCD27T0
Brand NameServer Technology
Product SeriesPRO2
Product NamePRO2 24-Outlets PDU
Marketing Information

The Server Technology® PRO2 Switched PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS® technology provides billing grade accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The PRO2 Switched "Primary" PDU can be connected to as many as three (with optional module) PRO2 Switched "Link" PDUs to extend the network access to the redundant or secondary power feed without the risks of a daisy chain linking configuration.

Product TypePDU
Technical Information
PDU TypeSwitched
PhaseThree Phase
Plug/Connector TypeIEC 60309 3P+N+G 6Hr 60A
Receptacle TypeCX
Receptacle Detail24 x CX
Protection Type
  • Branch Circuit
  • Circuit Protection
  • Circuit Breaker
  • Fuse
Locking ReceptaclesP-Lock
FeaturesLED Display
Load Capacity (Watt)34.50 kW
Power Description
Input Voltage
  • 415 V AC
  • 230 V AC
Output Voltage240 V AC
Power Rating (Watt)34.50 kW
Input Current60 A
Input Frequency60 Hz
Circuit BreakerYes
Management
Management
  • HTTP/HTTPS
  • TLSv1.2
  • SSHv2
  • Telnet
  • SNMPv2c
  • v3 (GET, SET, Traps)
  • IPv4
  • IPv6
  • LDAPv3/LDAPS
  • TACACS+
  • RADIUS
  • FTP/SFTP
Interfaces/Ports
Network (RJ-45)Yes
Physical Characteristics
Mount Type
  • Rack-mountable
  • Cabinet-mountable
Height70" (1778 mm)
Width2.20" (55.88 mm)
Depth3" (76.20 mm)
Environmental Conditions
Minimum Operating Temperature32°F (0°C)
Maximum Operating Temperature140°F (60°C)
Minimum Operating Humidity8%
Maximum Operating Humidity90%
Minimum Storage Temperature-40°F (-40°C)
Maximum Storage Temperature185°F (85°C)
Miscellaneous
Package Contents
  • PRO2 24-Outlets PDU
  • Standard Button Mounts
Application/Usage
  • IT Equipment
  • Server Rack/Cabinet
Certifications & Standards

Safety (Listed & Certified, cTUVus mark):

  • UL 62368-1
  • CSA C22.2 No. 62368-1

EMC:

  • FCC Part 15 Subpart B Sections 15.107 & 15.109, Class A
  • CANICES-003, Class A
ConditionNo
Warranty
Limited Warranty2 Year
miscellaneous kits (2)

Part No. KIT-0020

Server Technology (KIT0020) Miscellaneous Kits

LEGRAND MOUNTING BUTTON KIT

Part No. KIT-PRO2LINK-01D

Server Technology (KIT-PRO2LINK-01D) Miscellaneous Kit

Legrand-Servertech PRO2 Multi-Linking (Dongle) Kit, (1) Detached Link Module, (2) 6.4 m / 21 ft linking Cables, (1) 305 mm (1 ft) PDU to Module Cable

temperature & humidity sensors (2)

Part No. EMTH-2-10

Temp & Humidity Probe

LEGRAND-SERVERTECH COMBO TEMP & HUMIDITY PROBE

Part No. EMCU-1-1C

Server Technology (EMCU11C) Temperature & Humidity Sensors

LEGRAND ENVIRONMENTAL MONITOR CONTROL UNIT SUPPLIED WITH ONE (1) TEMPERATURE ANDHUMIDITY PROBE (PART NUMBER EMTH-2-10) WITH 10 FT (3 M) CORD, STI