Server Technology PRO2 C2WG24SN-5PJN5D6 24-Outlets PDU

Part No. C2WG24SN-5PJN5D6

by Server Technology, Inc

Server Technology PRO2 C2WG24SN-5PJN5D6 24-Outlets PDU

Switched - IEC 60309 3P+N+G 6Hr - 18 x IEC 60320 C13, 6 x CX - 415 V AC - Network (RJ-45) - Rack-mountable, Cabinet-mountable

Part No. C2WG24SN-5PJN5D6

by Server Technology, Inc

$4422.99
General Information
ManufacturerServer Technology, Inc
Manufacturer Part NumberC2WG24SN-5PJN5D6
Brand NameServer Technology
Product SeriesPRO2
Product ModelC2WG24SN-5PJN5D6
Product NamePRO2 C2WG24SN-5PJN5D6 24-Outlets PDU
Marketing Information

The Server Technology® PRO2 Switched POPS PDU provides control of outlet power and local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS® and POPS® technology provides billing-grade accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input and at each output. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The PRO2 Switched POPS "Master" PDU can be connected to as many as three (with optional module) PRO2 Switched POPS "Link" PDUs to extend the network access to the redundant or secondary power feed without the risks of a daisy chain linking configuration.

Product TypePDU
Technical Information
PDU TypeSwitched
PhaseThree Phase
Plug/Connector TypeIEC 60309 3P+N+G 6Hr
Receptacle Type
  • IEC 60320 C13
  • CX
Receptacle Detail
  • 18 x IEC 60320 C13
  • 6 x CX
Protection Type
  • Circuit Protection
  • Single Pole
Power Description
Input Voltage415 V AC
Power Rating (Watt)17.30 kW
Input Current30 A
Management
Management
  • HTTP/HTTPS
  • TLSv1.2, SSHv2
  • Telnet
  • SNMPv2c
  • IPv4
  • IPv6
  • LDAPv3/LDAPS
  • TACACS+
  • RADIUS
  • FTP/SFTP
  • v3 [GET, SET, Traps]
Interfaces/Ports
Network (RJ-45)Yes
Physical Characteristics
Mount Type
  • Rack-mountable
  • Cabinet-mountable
Height3.50" (88.90 mm)
Width17.20" (436.88 mm)
Depth17.50" (444.50 mm)
Miscellaneous
Package Contents
  • PRO2 C2WG24SN-5PJN5D6 24-Outlets PDU
  • Mounting Brackets
Country of OriginUnited States
ConditionNo
Warranty
Limited Warranty2 Year
miscellaneous kits (1)

Part No. KIT-PRO2LINK-01D

Server Technology (KIT-PRO2LINK-01D) Miscellaneous Kit

Legrand-Servertech PRO2 Multi-Linking (Dongle) Kit, (1) Detached Link Module, (2) 6.4 m / 21 ft linking Cables, (1) 305 mm (1 ft) PDU to Module Cable

temperature & humidity sensors (2)

Part No. EMTH-2-10

Temp & Humidity Probe

LEGRAND-SERVERTECH COMBO TEMP & HUMIDITY PROBE

Part No. EMCU-1-1C

Server Technology (EMCU11C) Temperature & Humidity Sensors

LEGRAND ENVIRONMENTAL MONITOR CONTROL UNIT SUPPLIED WITH ONE (1) TEMPERATURE ANDHUMIDITY PROBE (PART NUMBER EMTH-2-10) WITH 10 FT (3 M) CORD, STI