Server Technology PRO2 Smart 24-Outlets PDU

Part No. C2S24SP-YCLN5D6

by Server Technology, Inc

Server Technology PRO2 Smart 24-Outlets PDU

Monitored - NEMA L21-30P - 18 x IEC 60320 C13, 6 x CX - 230 V AC - Branch Circuit, Circuit Protection, Fuse, Double Pole - Network (RJ-45) - Rack-mountable, Cabinet-mountable

Part No. C2S24SP-YCLN5D6

by Server Technology, Inc

$2992.99
General Information
ManufacturerServer Technology, Inc
Manufacturer Part NumberC2S24SPYCLN5D6
Brand NameServer Technology
Product LinePRO2
Product SeriesSmart
Product NamePRO2 Smart 24-Outlets PDU
Marketing Information

The Server Technology® PRO2 Smart PDU provides local LED input current monitoring, allowing IT personnel to determine safe levels of loading on a per-phase basis while installing equipment into the rack/cabinet. The integral PIPS® technology provides billing-grade accurate measurement of current, voltage, active power, apparent power, power factor, crest factor, and accumulated energy at the input. These power data points, along with temperature and humidity measurements (provided via optional probes), are accessible through the built-in Web and CLI interfaces as well as through SNMP. The PRO2 Smart "Primary" PDU can be connected to as many as three (with optional module) PRO2 Smart "Link" PDU to extend the network access to the redundant or secondary power feed without the risks of a daisy chain linking configuration.

Product TypePDU
Technical Information
PDU TypeMonitored
PhaseThree Phase
Plug/Connector TypeNEMA L21-30P
Receptacle Type
  • IEC 60320 C13
  • CX
Receptacle Detail
  • 18 x IEC 60320 C13
  • 6 x CX
Protection Type
  • Branch Circuit
  • Circuit Protection
  • Fuse
  • Double Pole
FeaturesLED Display
Power Description
Input Voltage230 V AC
Output Voltage208 V AC
Power Rating (Watt)8.60 kW
Input Current30 A
Input Frequency60 Hz
Circuit BreakerYes
Management
Management
  • HTTP/HTTPS
  • TLSv1.2
  • SSHv2
  • Telnet
  • SNMPv2c
  • v3 (GET, SET, Traps)
  • IPv4 and IPv6
  • LDAPv3/LDAPS
  • TACACS+
  • RADIUS
  • FTP/SFTP
  • RS-232
Interfaces/Ports
Network (RJ-45)Yes
Physical Characteristics
Mount Type
  • Rack-mountable
  • Cabinet-mountable
Height3.50" (88.90 mm)
Width17.20" (436.88 mm)
Depth10" (254 mm)
Environmental Conditions
Minimum Operating Temperature32°F (0°C)
Maximum Operating Temperature140°F (60°C)
Minimum Operating Humidity8%
Maximum Operating Humidity90%
Minimum Storage Temperature-40°F (-40°C)
Maximum Storage Temperature185°F (85°C)
Miscellaneous
Package Contents
  • PRO2 Smart 24-Outlets PDU
  • Standard Button Mounts
Application/UsageIT Equipment
Certifications & Standards

Safety (Listed & Certified, cTUVus mark):

  • UL 62368-1
  • CSA C22.2 No. 62368-1

EMC:

  • FCC Part 15 Subpart B Sections 15.107 & 15.109, Class A
  • CANICES-003, Class A
ConditionNo
Warranty
Limited Warranty2 Year
miscellaneous kits (2)

Part No. KIT-PRO2LINK-01D

Server Technology (KIT-PRO2LINK-01D) Miscellaneous Kit

Legrand-Servertech PRO2 Multi-Linking (Dongle) Kit, (1) Detached Link Module, (2) 6.4 m / 21 ft linking Cables, (1) 305 mm (1 ft) PDU to Module Cable

Part No. KIT-0020

Server Technology (KIT0020) Miscellaneous Kits

LEGRAND MOUNTING BUTTON KIT

temperature & humidity sensors (2)

Part No. EMTH-2-10

Temp & Humidity Probe

LEGRAND-SERVERTECH COMBO TEMP & HUMIDITY PROBE

Part No. EMCU-1-1C

Server Technology (EMCU11C) Temperature & Humidity Sensors

LEGRAND ENVIRONMENTAL MONITOR CONTROL UNIT SUPPLIED WITH ONE (1) TEMPERATURE ANDHUMIDITY PROBE (PART NUMBER EMTH-2-10) WITH 10 FT (3 M) CORD, STI